  • Powerful multiplexed config. with 64-ch active aperture
  • No TFM, can be upgraded later
  • Compact, rugged, scalable - unlimited probes & groups

Lead Time: 2-4 months (Standard/typical lead time)

Highlights

Description

PANTHER™ Phased Array system 64:128PR channels. TFM not included. Compact housing designed for IP54, USB3, 3 encoders, PRF 30kHz, 1 IPEX connector. C/w AC adapter. C/w rugged case. Computer / ACQUIRE / CIVA Analysis software not included.
More Information
A-Scan height (dynamic range) Up to 800%
Adaptive TFM (ATFM) No
Array connectors 1x IPEX
Cooling Sealed with external fans
Data storage Depending Associated Computer
Maximum active aperture 64
Nb. of receiving elements 128
Paperless Reporting Yes
Pulser (PAUT) voltage From 20 V to 100 V (with 1 V steps)
Pulser (UT) voltage From 20 V to 100 V (with 1 V steps)
Remote control availability Yes
Rope access applications No
Setup creation/management Setup wizards, application
Total Focusing Method (TFM) No
Volume 10 L (610 in3)
Compliance EN ISO 18563-1:2015 GR2, AITM-00016 Issue5 table7;
Data readback on PC software Yes
Defect table (for reporting) No
Digitizing 16-bit resolution
Encoder inputs 3-axis, 5V optocoupled
Encoders and I/O connectors 1x microD25
Frequency range 0.3 MHz to 20 MHz
Gain range (PAUT) Up to 120 dB (0.1 dB steps)
Gain range (UT-TOFD) Up to 120 dB (0.1 dB steps)
Gates Floating and tracking for repeatable and reliable results
Input impedance 50 Ohms
Operating temperature 0°C to 50°C (32°F to 122°F)
Optional PC software available Yes
Programmable alarms Yes
Pulse type (PAUT) Bipolar square pulse
Pulse type (UT-TOFD) Bipolar square pulse
Pulse width 20 ns to 2000 ns
Support custom application and probes Yes
UT/TOFD connectors 4x LEMO 00
Weight (without batteries) 6.6 kg (14.5 lb)
Power supply/requirements DC-16-30 V, 90W, AC-100-240 V
Synchronization with I/O No
Full screen mode No
External trigger Yes
Operating humidity 12%RH – 78%RH
Programmable outputs No
Pulser (PAUT) fall time <6 ns
Pulser (UT-TOFD) fall time <6ns
Reload data from defect table Yes
Storage Depending associated computer
Storage temperature -20°C to 70°C (-4°F to 158°F)
Video output Depending Associated Computer

Depending on the instrument configuration:

  • Laboratory and research
  • Industrial applications
  • High-speed UT/TOFD/PAUT/TFM/PWI inspections
  • Integration with Software development kit (SDK)
Panther™ 64:128PR with PAUT, UT, TOFD without TFM
© 2021 Eddyfi NDT Inc.

Generating your quote will provide a quote number for future reference. Easy and non-binding.