Panther™ 128:256PR with PAUT, UT, TOFD, TFM 128-ch.

USD 158,170.00
In stock
SKU
PANTHER-128:256PR-TFM
  • Superior multiplexed config. with 128-ch active aperture
  • Superior TFM capabilities with real-time TFM, FMC, PWI
  • Compact, rugged, scalable - unlimited probes & groups

Lead Time: On request (Standard/typical lead time)

Highlights

Description

PANTHER™ Phased Array system 128:256PR channels with real time TFM 128. Two Compact 64:128 boxes, 2 USB3, 3 encoders, PRF 30kHz, 2 IPEX connector (1-128 & 129 -256 channels). C/w rugged cases. Computer / ACQUIRE / CIVA Analysis software not included.
More Information
A-Scan height (dynamic range) Up to 800%
Adaptive TFM (ATFM) Yes
Array connectors 1x IPEX
Cooling Sealed with external fans
Data storage Depending Associated Computer
Maximum active aperture 128
Nb. of receiving elements 256
Paperless Reporting Yes
Pulser (PAUT) voltage From 20 V to 100 V (with 1 V steps)
Pulser (UT) voltage From 20 V to 100 V (with 1 V steps)
Real-time TFM refresh rate Up to 600Hz
Remote control availability Yes
Rope access applications No
Setup creation/management Setup wizards, application
Total Focusing Method (TFM) Yes
Compliance EN ISO 18563-1:2015 GR2, AITM-00016 Issue5 table7;
Data readback on PC software Yes
Defect table (for reporting) No
Digitizing 16-bit resolution
Encoders and I/O connectors 1x microD25
Frequency range 0.3 MHz to 20 MHz
Gain range (PAUT) Up to 120 dB (0.1 dB steps)
Gain range (UT-TOFD) Up to 120 dB (0.1 dB steps)
Gates Floating and tracking for repeatable and reliable results
Input impedance 50 Ohms
Optional PC software available Yes
Programmable alarms Yes
Pulse type (PAUT) Bipolar square pulse
Pulse type (UT-TOFD) Bipolar square pulse
Pulse width 20 ns to 2000 ns
Support custom application and probes Yes
UT/TOFD connectors 4x LEMO 00
Synchronization with I/O No
Full screen mode No
Connectivity Depending Associated Computer
Dimensions (W x D x H) 298x220x156 mm (x2)
External trigger Yes
Encoder inputs 3-axis, 5V optocoupled
IP rating IP50, IP54 with protection box
Operating humidity 12%RH – 78%RH
Operating temperature 0°C to 50°C (32°F to 122°F)
Power supply/requirements DC-16-30 V, 180W, AC-100-240 V
Programmable outputs No
Pulser (PAUT) fall time <6 ns
Pulser (UT-TOFD) fall time <6ns
Reload data from defect table Yes
Supported Technologies/Techniques UT, TOFD, PAUT, TFM, ATFM, PWI
Storage Depending associated computer
Storage temperature -20°C to 70°C (-4°F to 158°F)
Volume 20 L (1220 in3)
Weight (without batteries) 13.2 kg (29.0 lb)
Video output Depending Associated Computer

Depending on the instrument configuration:

  • Laboratory and research
  • Industrial applications
  • High-speed UT/TOFD/PAUT/TFM/PWI inspections
  • Integration with Software development kit (SDK)
Panther™ 128:256PR with PAUT, UT, TOFD, TFM 128-ch.
© 2021 Eddyfi NDT Inc.

Generating your quote will provide a quote number for future reference. Easy and non-binding.